DYNAMIC AND SEISMIC HEALTH MONITORING OF A HISTORIC MASONRY TOWER

The paper presents some results of the continuous dynamic/seismic monitoring program carried out on the tallest historic tower in Mantua, Italy. This project follows an extensive diagnostic investigation aimed at assessing the structural condition of the tower after the Italian earthquakes of May 2012.
A simple dynamic monitoring system was installed in the tower to evaluate the dynamic response especially to the expected sequence of far-field earthquakes and to check the possible evolution of the natural frequencies; the response to ambient excitation has been continuously collected in 1-hour records since late December 2012.
The paper summarizes the results of the continuous dynamic monitoring for a period of 8 months, highlighting the effect of temperature on automatically identified natural frequencies, the dynamic response to few seismic events and the key role of permanent dynamic monitoring in the diagnosis of the investigated historic building.

 

$2.00Add to Cart

Antonella Saisi, Carmelo Gentile, Marco Guidobaldi